- A vulnerability classified as critical was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. This vulnerability affects unknown code of the file /admin/network/diag_pinginterface. The manipulation of the argument diag_ping leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
- Source
- cna@vuldb.com
- NVD status
- Analyzed
CVSS 4.0
- Type
- Secondary
- Base score
- 5.1
- Impact score
- -
- Exploitability score
- -
- Vector string
- CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Severity
- MEDIUM
CVSS 3.1
- Type
- Primary
- Base score
- 7.2
- Impact score
- 5.9
- Exploitability score
- 1.2
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Severity
- HIGH
CVSS 2.0
- Type
- Secondary
- Base score
- 5.8
- Impact score
- 6.4
- Exploitability score
- 6.4
- Vector string
- AV:N/AC:L/Au:M/C:P/I:P/A:P
- Hype score
- Not currently trending
[
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:engeniustech:enh1350ext_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0AD524C6-198C-405D-BA83-76C4D8F94EB0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:engeniustech:enh1350ext:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F4E8D70A-F5C2-4714-A398-26F7700D7E94"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:engeniustech:ens620ext_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "170D8BD6-2C90-4BB5-A6AA-DB18A743C788"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:engeniustech:ens620ext:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CB739DD5-DDF0-4AA3-8114-8D31A52EE71F"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:engeniustech:ens500-ac_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3C6AF42E-8CD1-418F-906E-65959337E39F"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:engeniustech:ens500-ac:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "07C3A46A-BB2E-4A7A-BA32-7E02E75E8AE0"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
]