Overview
- Description
- Improper Neutralization of Input During Web Page Generation (CWE-79) in the Controller 6000 and Controller 7000 diagnostic webpage allows an attacker to modify Controller configuration during an authenticated Operator's session. This issue affects: Controller 6000 and Controller 7000 9.10 prior to vCR9.10.240816a (distributed in 9.10.1530 (MR2)), 9.00 prior to vCR9.00.240816a (distributed in 9.00.2168 (MR4)), 8.90 prior to vCR8.90.240816a (distributed in 8.90.2155 (MR5)), 8.80 prior to vCR8.80.240816b (distributed in 8.80.1938 (MR6)), all versions of 8.70 and prior.
- Source
- disclosures@gallagher.com
- NVD status
- Awaiting Analysis
Risk scores
CVSS 3.1
- Type
- Secondary
- Base score
- 6.1
- Impact score
- 2.7
- Exploitability score
- 2.8
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:L/A:L
- Severity
- MEDIUM
Weaknesses
- disclosures@gallagher.com
- CWE-79
Social media
- Hype score
- Not currently trending