Overview
- Description
- Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.
- Source
- vultures@jpcert.or.jp
- NVD status
- Awaiting Analysis
Risk scores
CVSS 3.1
- Type
- Secondary
- Base score
- 9.8
- Impact score
- 5.9
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- CRITICAL
Weaknesses
- 134c704f-9b21-4f2e-91b3-4a467353bcc0
- CWE-78
Social media
- Hype score
- Not currently trending