CVE-2024-3699

Published Jun 10, 2024

Last updated 5 months ago

Overview

Description
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all drEryk Gabinet installations.This issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0.
Source
cvd@cert.pl
NVD status
Analyzed

Risk scores

CVSS 4.0

Type
Secondary
Base score
9.3
Impact score
-
Exploitability score
-
Vector string
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:C/RE:M/U:Red
Severity
CRITICAL

CVSS 3.1

Type
Primary
Base score
9.8
Impact score
5.9
Exploitability score
3.9
Vector string
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Severity
CRITICAL

Weaknesses

nvd@nist.gov
CWE-798
cvd@cert.pl
CWE-798

Social media

Hype score
Not currently trending

Configurations