CVE-2024-42018

Published Oct 11, 2024

Last updated 11 days ago

Overview

Description
An issue was discovered in Atos Eviden SMC xScale before 1.6.6. During initialization of nodes, some configuration parameters are retrieved from management nodes. These parameters embed credentials whose integrity and confidentiality may be important to the security of the HPC configuration. Because these parameters are needed for initialization, there is no available mechanism to ensure access control on the management node, and a mitigation measure is normally put in place to prevent access to unprivileged users. It was discovered that this mitigation measure does not survive a reboot of diskful nodes. (Diskless nodes are not at risk.) The mistake lies in the cloudinit configuration: the iptables configuration should have been in the bootcmd instead of the runcmd section.
Source
cve@mitre.org
NVD status
Awaiting Analysis

Risk scores

CVSS 3.1

Type
Secondary
Base score
7.7
Impact score
4
Exploitability score
3.1
Vector string
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N
Severity
HIGH

Weaknesses

134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE-922

Social media

Hype score
Not currently trending