CVE-2024-43652

Published Jan 9, 2025

Last updated 2 months ago

Overview

Description
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
Source
csirt@divd.nl
NVD status
Received

Risk scores

CVSS 4.0

Type
Secondary
Base score
9.3
Impact score
-
Exploitability score
-
Vector string
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:Y/R:U/V:D/RE:M/U:X
Severity
CRITICAL

CVSS 3.1

Type
Secondary
Base score
8.8
Impact score
5.9
Exploitability score
2.8
Vector string
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Severity
HIGH

Weaknesses

csirt@divd.nl
CWE-78

Social media

Hype score
Not currently trending