Overview
- Description
- A vulnerability has been identified in ModelSim (All versions < V2024.3), Questa (All versions < V2024.3). vish2.exe in affected applications allows a specific DLL file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch vish2.exe from a user-writable directory.
- Source
- productcert@siemens.com
- NVD status
- Analyzed
Risk scores
CVSS 4.0
- Type
- Secondary
- Base score
- 5.4
- Impact score
- -
- Exploitability score
- -
- Vector string
- CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Severity
- MEDIUM
CVSS 3.1
- Type
- Primary
- Base score
- 7.3
- Impact score
- 5.9
- Exploitability score
- 1.3
- Vector string
- CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
- Severity
- HIGH
Weaknesses
- productcert@siemens.com
- CWE-427
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:modelsim:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F71515BC-BF05-4F67-B931-F5F6FE5143F4", "versionEndExcluding": "2024.3" } ], "operator": "OR" } ] }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:questa:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0A126954-0467-4268-8135-AAFFCB52C10C", "versionEndExcluding": "2024.3" } ], "operator": "OR" } ] } ]