- Description
- A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.
- Source
- prodsec@nozominetworks.com
- NVD status
- Received
CVSS 3.1
- Type
- Secondary
- Base score
- 9.8
- Impact score
- 5.9
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- CRITICAL
- prodsec@nozominetworks.com
- CWE-78
- Hype score
- Not currently trending
More than Two Dozen Flaws Identified in Advantech Industrial Wi-Fi Access Points – Patch ASAP: CVE-2024-50370 CVE-2024-50374 CVE-2024-50375 CVE-2024-50376 CVE-2024-50359 https://t.co/Vojq55h9Oq
@vault33org
29 Nov 2024
4 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
[CVE-2024-50374: CRITICAL] Vulnerability CWE-78 affecting Advantech devices EKI-6333AC-2G, EKI-6333AC-2GD, and EKI-6333AC-1GPO allows remote unauthenticated users to run malicious commands with root privileges.#cybersecurity,#vulnerability https://t.co/Setpgtm42D https://t.co/Skj
@CveFindCom
26 Nov 2024
31 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
CVE-2024-50374 A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by A… https://t.co/1e1tukUTrl
@CVEnew
26 Nov 2024
231 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes