Overview
- Description
- A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2). Affected devices do not properly validate input in configuration fields of the iperf functionality. This could allow an unauthenticated remote attacker to execute arbitrary code on the device.
- Source
- productcert@siemens.com
- NVD status
- Analyzed
Risk scores
CVSS 4.0
- Type
- Secondary
- Base score
- 8.6
- Impact score
- -
- Exploitability score
- -
- Vector string
- CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Severity
- HIGH
CVSS 3.1
- Type
- Primary
- Base score
- 9.8
- Impact score
- 5.9
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- CRITICAL
Weaknesses
- nvd@nist.gov
- NVD-CWE-noinfo
- productcert@siemens.com
- CWE-20
Social media
- Hype score
- Not currently trending
[CVE-2024-50557: HIGH] Vulnerability alert: Various SCALANCE and RUGGEDCOM devices (versions < V8.2) have a flaw allowing remote attackers to execute code due to improper input validation in iperf function.#cybersecurity,#vulnerability https://t.co/84hgoarPAb https://t.co/yjDx
@CveFindCom
12 Nov 2024
48 Impressions
1 Retweet
0 Likes
0 Bookmarks
0 Replies
0 Quotes
CVE-2024-50557 A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All … https://t.co/Nq3vE4MNiA
@CVEnew
12 Nov 2024
193 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\(4g\\)_eu_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "4F7981A8-C60A-45EE-92E5-8149A3F7760F", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ruggedcom_rm1224_lte\\(4g\\)_eu:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "03D8CF59-D9D4-4C50-A6E6-D6B5BDB31AEC" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\(4g\\)_nam_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6BF2D6E7-45CD-4303-B9A9-A576BC2F1B6F", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ruggedcom_rm1224_lte\\(4g\\)_nam:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "400ACE99-AF15-4C20-9A6D-F8584DA5C7CE" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m804pb_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "077F8316-E68A-4787-88EF-8016D8F06F00", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "C6EBA42A-93FF-4883-8626-EF78D38374D3" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m812-1_\\(annex_a\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "780808FF-1144-4AEE-9E72-DE5B19870E2F", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m812-1_\\(annex_a\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "B680E815-D9EF-41BC-A198-85332738B1B9" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m812-1_\\(annex_b\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C3148BA6-091B-4203-B12E-2FFCEA1DB22D", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m812-1_\\(annex_b\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "0895418F-A4C6-40D3-8544-5AF3F5B54709" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m816-1_\\(annex_a\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0BCD7E43-4CF9-4937-8A62-4B42FE03584F", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m816-1_\\(annex_a\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7A1636E7-BF41-4BF6-8609-9675956FB947" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m816-1_\\(annex_b\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A2594F8F-9DEF-4FC4-9068-B5A29C4DBA92", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m816-1_\\(annex_b\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "06E70F60-33E2-472F-9B25-FE19B964220B" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m826-2_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "EDF99EF5-12B4-45EE-9BC3-59E9F744376B", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m826-2:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "60458734-FF87-48E9-9B63-5AB9EA5ED0E5" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m874-2_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1DD142E4-6F7F-4751-93B6-C3508A0828DA", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m874-2:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "C933ED27-2206-4734-8EB8-6A6431D1FBF1" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m874-3_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1B7D6063-EB3D-4150-9B89-D62C38E65787", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m874-3:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "D3258DC7-0461-4C65-8292-85C9965EA83D" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m874-3_\\(cn\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F8D5BDB5-AE39-472C-9A76-243DC01C97F8", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m874-3_\\(cn\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "71B11BE1-57EB-43AB-8F7A-AFE5BA28D34A" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m876-3_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "BFE41F12-80FC-46CE-BBFA-E11695C56E30", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m876-3:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "BD221BA9-3448-49E4-B3A3-D88B939785AC" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m876-3_\\(rok\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D5A8F79E-C849-4D3B-9103-8068DD84DAEC", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m876-3_\\(rok\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "A3FA80AA-4869-46BF-8A1B-17C54219338C" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m876-4_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FA02FE0C-5813-4994-9887-BE0AB1344FEB", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m876-4:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "94E4CCE9-71F7-4960-B7DE-5298EFB7C619" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m876-4_\\(eu\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B43540C5-9208-42C9-BDB6-2D6C0EB665C7", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m876-4_\\(eu\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "3886E130-C39C-43D2-8B1F-F773874F8002" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m876-4_\\(nam\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "EC56B2F3-EEF5-4891-92EE-917F6EA685E7", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m876-4_\\(nam\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "CDBED616-1074-44CE-98C8-48A5387A5DAF" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_mum853-1_\\(a1\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "BD477A4C-4C41-4068-872C-2D633E2DB5C9", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_mum853-1_\\(a1\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "DC884995-EA34-4EFA-8B3A-5C7B9BC71C32" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_mum853-1_\\(b1\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "01EEE560-AC67-47FE-8B30-F699CAF951FF", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_mum853-1_\\(b1\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "A94E232B-12ED-4E9D-A6D7-C66391C48F06" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_mum853-1_\\(eu\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "5C0D7706-40DC-4598-B24C-9BD7B20B31F4", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_mum853-1_\\(eu\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "94AF78F7-3DF5-40FA-A496-4523183DB792" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_mum856-1_\\(a1\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6D13A44E-DE1F-4BE3-AD0B-FCF4E8DAA9E7", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_mum856-1_\\(a1\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "FF849848-87EA-41D5-8E19-871A306D332A" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_mum856-1_\\(b1\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C56063A9-5A2A-4F19-AAAC-A40A01D0D69F", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_mum856-1_\\(b1\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "77E5245F-8AA7-4132-AA7F-1FE4F86B703E" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_mum856-1_\\(cn\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "27486547-EDF2-45C2-84FF-7B74D75304F6", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_mum856-1_\\(cn\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "2B05B62B-1B41-4A3D-8591-57B4D0EF476F" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_mum856-1_\\(eu\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "124DE318-3EFE-4FDA-8306-462BB936F892", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_mum856-1_\\(eu\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "A219D2B9-1D71-4831-BD0B-790B7057344C" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_mum856-1_\\(row\\)_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "973C1E5B-8A98-4345-8BE3-A4B7B39EEF4F", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_mum856-1_\\(row\\):-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "8D6FED00-E40C-458A-8D5C-9B1826DBAE24" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s615_eec_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7246F2E8-0A0E-4020-B806-421DB0B91C0B", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s615_eec:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "AA5D94EA-C407-446F-B98F-F647ACBBA010" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F16CD316-4D89-45B7-83C1-138236898C0A", "versionEndExcluding": "8.2" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7" } ], "operator": "OR" } ], "operator": "AND" } ]