- Description
- A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 5). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
- Source
- productcert@siemens.com
- NVD status
- Analyzed
CVSS 4.0
- Type
- Secondary
- Base score
- 7.3
- Impact score
- -
- Exploitability score
- -
- Vector string
- CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Severity
- HIGH
CVSS 3.1
- Type
- Primary
- Base score
- 7.8
- Impact score
- 5.9
- Exploitability score
- 1.8
- Vector string
- CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Severity
- HIGH
- Hype score
- Not currently trending
SSA-730188 is the last contribution of the year that includes three CVEs (CVE-2024-54093, CVE-2024-54094, CVE-2024-54095). This year I reported dozens of memory corruption vulnerability to Siemens. Looking forward to contribute more next year 🤘 https://t.co/gNVmmiYw12
@zeifan
11 Dec 2024
288 Impressions
1 Retweet
11 Likes
1 Bookmark
0 Replies
0 Quotes
CVE-2024-54094 Heap-Based Buffer Overflow Vulnerability in Solid Edge SE2024 Solid Edge SE2024 has a vulnerability in all versions before V224.0 Update 5. The problem is a heap-based buffer overflow. It happens w... https://t.co/mTk8EVvQGj
@VulmonFeeds
10 Dec 2024
29 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
A new vulnerability with increased severity was disclosed for Siemens Solid Edge SE2024 (CVE-2024-54094) https://t.co/CSx3ZABXdT
@vuldb
10 Dec 2024
66 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
[
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D3887095-4E46-43B0-8A1E-4938EB474419",
"versionEndExcluding": "224.0"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A0119E8F-1FAF-4A3B-B6E9-20F78360FC82"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "829C4AEB-7C8D-408B-A79C-8684753F45E1"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1E8FB23E-280D-46FD-BD44-5D4552639E00"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0003:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CA2417A0-DD31-46FC-8D5A-9128B86C9352"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0004:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3CA9C494-767C-4CFA-AB07-106298B7B2C4"
}
],
"operator": "OR"
}
]
}
]